// General Surgery - Gynecology - Urology - MIS - OEM China

Disposable Laparoscopic Trocars — 5 / 10 / 12 / 15mm

Bladeless smooth-tip or bladed obturator. Multi-seal CO2 valve rated to 20mmHg. Reducer caps included. EO sterile, CE marked, ISO 13485. In stock from 500 pcs. Custom OEM available.

Disposable laparoscopic trocar 5mm 10mm 12mm 15mm bladeless OEM EKINSUN
Laparoscopic trocar Trocar view 2 Manufacturing facility Medical components

100% of units CO2 seal-tested at 20mmHg before EO sterilization. Reducer caps for 10mm and 5mm instruments included with every 12mm trocar.

In Stock MOQ 500 pcs Custom OEM / ODM CE - ISO 13485

EKINSUN manufactures single-use plastic laparoscopic trocars for general surgery, gynecology, urology, and minimally invasive surgical procedures worldwide. Produced in our ISO 13485-certified injection molding facility in Guangdong, China. Available in four sizes with two obturator options (bladeless and bladed) and two valve types (trumpet and duckbill).

Sizes available5mm / 10mm / 12mm / 15mm
Obturator typesBladeless (smooth-tip dilating) / Bladed / Optical (clear tip)
Valve typesTrumpet (flap) valve / Duckbill (slit) valve
CO2 seal pressure20mmHg (exceeds standard working pressure of 12 to 15mmHg)
Working lengths70mm standard / 100mm extended / 150mm bariatric
Reducer caps (12mm)12mm to 10mm + 12mm to 5mm (included)
Thread-lock optionAvailable - screw-in cannula design
Cannula materialMedical ABS / Polycarbonate
Obturator materialPolycarbonate (bladeless) / ABS + PC tip (bladed)
SterilizationEO sterile - SAL 10e-6 - single-use
Shelf life3 years from sterilization date
CertificationCE - ISO 13485 - ISO 10993
Stock lead time7 to 10 business days
Custom lead time30 to 45 days from approved spec

GET PRICING - FREE SAMPLES - OEM QUOTE

Request OEM Quote WhatsApp - Reply Within Hours

FREE SAMPLES FOR DISTRIBUTORS - NDA ON REQUEST - CE DOCS SUPPLIED

Trocar Selection by Procedure and Port Role

ProcedureTypical Port ConfigurationTrocar Sizes Used
Laparoscopic cholecystectomy4-port standard1x 10-12mm (camera), 3x 5mm
Laparoscopic appendectomy3-port1x 10-12mm, 2x 5mm
Laparoscopic hysterectomy4-port1x 10-12mm, 2-3x 5mm
Laparoscopic colectomy4 to 5-port1x 12-15mm (stapler), 3-4x 5-10mm
Laparoscopic nephrectomy3 to 4-port1x 12mm, 2-3x 5-10mm
Robotic-assisted surgery4-arm configuration4x 8-12mm robotic ports + 1x assistant
Single-incision laparoscopy (SILS)Single port multi-channelCustom SILS port + 5mm working channels

Bladeless vs Bladed vs Optical — Detailed Comparison

FeatureBladeless (Smooth-tip)BladedOptical
Entry mechanismTissue dilation / spreadingSharp cuttingVisual layer-by-layer
Insertion force requiredModerateLowModerate
Best for patient BMINormal to overweightOverweight to obeseAny (highest control)
Vascular injury riskLowerModerateLowest
Visceral injury riskLowerModerateLowest
Port-site hernia riskLower (tissue spread)Higher (fascial cut)Lower
CostStandardStandardHigher
AvailabilityStockStockMOQ 500 pcs

Manufacturing — ISO 13485 Injection Molding

Laparoscopic trocars are precision-molded components where dimensional accuracy directly affects CO2 seal performance and instrument fit. EKINSUN's ISO 13485 injection molding facility uses validated molds with in-process dimensional monitoring and 100% post-molding CO2 seal testing on assembled units. Key manufacturing controls include:

  • Mold cavity dimensional control: inner cannula diameter tolerance held to plus or minus 0.05mm to ensure proper instrument fit and CO2 seal
  • Valve assembly validation: each valve mechanism assembled and tested for CO2 seal at 20mmHg before trocar packaging
  • Obturator tip geometry: bladeless dilating tip angle and surface finish controlled for consistent tissue spreading force
  • Reducer cap fit test: every reducer cap insertion-tested in trocar before packing to confirm correct fit and CO2 seal maintenance

This is the same facility and quality system used to manufacture our 3-way stopcocks, IV manifolds, and Luer lock connectors — all of which require equivalent dimensional precision.

OEM and Private Label Process

  1. Specify configuration — size, obturator type (bladeless/bladed/optical), valve type, working length, thread-lock requirement
  2. Label artwork — peel-pack label, outer carton, multilingual IFU. Languages: English, Spanish, German, French, Arabic, Portuguese
  3. Regulatory documentation — CE DoC, ISO 13485 cert, EO cert, batch CoA under your product name
  4. MOQ — 500 pcs per configuration for peel-pack label, 1000 pcs for carton printing
  5. Mixed orders — multiple sizes accepted in one purchase order when total meets overall MOQ

Complete your MIS surgical disposables sourcing: pair with our cervical and uterine balloon catheters for gynecologic procedures, percutaneous tracheotomy kits for ICU access procedures, and Foley catheters for peri-operative urinary drainage — all CE marked, from a single ISO 13485-certified supplier.

Related Products

Frequently Asked Questions

Bladeless trocars use a conical or pyramidal dilating tip that spreads tissue apart rather than cutting — reducing the risk of port-site bleeding, inadvertent visceral injury, and post-operative port-site hernia. Bladed trocars use a sharp cutting obturator that requires less insertion force, which is advantageous for obese patients with thick abdominal walls. Bladeless is the current preferred design for most laparoscopic procedures due to its superior safety profile. We supply both; bladeless is recommended for most indications.

All our trocars maintain gas-tight seal integrity at 20mmHg CO2 pressure — which is the standard upper limit of laparoscopic insufflation pressure (typical working pressure is 12 to 15mmHg). The multi-seal valve system is tested per ISO 8538 valve leak standard. Zero gas leakage at rated pressure across 100% of production units.

Each 12mm trocar includes two reducer caps: a 12mm-to-10mm reducer for use with 10mm laparoscopic instruments, and a 12mm-to-5mm reducer for 5mm instruments. This allows a single 12mm trocar to accept instruments of three different diameters without loss of CO2 seal — increasing port flexibility and reducing the number of different trocars needed in a laparoscopic setup. Reducer caps are individually sterile wrapped and packed with the trocar.

Our 8mm and 12mm versions are designed with dimensions compatible with standard robotic arm trocar adapters. Compatibility varies by robotic system generation — contact us with your specific robot model (da Vinci Si, X, Xi, or Intuitive Ion) for confirmation. Custom robotic-specific trocar dimensions are available at 500 pcs MOQ.

Standard working lengths are 70mm (standard), 100mm (extended), and 150mm (bariatric/obese). Extended and bariatric length trocars are required when the distance from skin to peritoneum exceeds the standard 70mm length — common in morbidly obese patients where a standard trocar may not reach the peritoneal cavity. Specify working length at inquiry.

Trumpet (flap) valve trocars use a spring-loaded flap mechanism that opens when an instrument is inserted and closes when it is withdrawn — providing positive CO2 seal even when instruments are not present. Duckbill valve trocars use a slit-valve mechanism that is simpler and lower profile but may allow minor gas leak when no instrument is present. Trumpet valve is standard for most laparoscopic applications; duckbill is preferred for NOTES and single-port procedures where a lower-profile trocar is needed.

Yes. Thread-lock trocars have a helical thread on the outer cannula that screws into the abdominal wall, preventing trocar displacement during instrument exchanges — particularly important for obese patients, prolonged procedures, and robotic surgery where external trocar manipulation is limited. Available from 500 pcs MOQ.

500 pcs per size for custom peel-pack label. 1000 pcs for outer carton printing with your brand. Mixed-size orders (e.g. 200 pcs x 5mm + 300 pcs x 12mm) accepted when total order meets 500 pcs overall. CE documentation under your product name supplied.

Yes. Each trocar is individually EO sterilized in a peel-pack. SAL 10e-6. Shelf life 3 years from sterilization date. The obturator and cannula are packed as a complete assembled unit ready for immediate use at the sterile field.

Cannula: medical-grade ABS or polycarbonate (PC) depending on size — high impact strength, autoclave-temperature resistant for dimensional stability during EO sterilization. Obturator: ABS with polycarbonate tip for the bladed version; PC throughout for the bladeless dilating tip version. All materials meet ISO 10993 biocompatibility requirements. Material certificates available per batch.

Yes. Optical trocars have a transparent obturator tip that allows a 0-degree laparoscope to be inserted into the obturator during initial entry, providing real-time visualization of the tissue layers as the trocar advances through the abdominal wall. Available in 5mm and 12mm from 500 pcs MOQ. Lead time 30 to 45 days for first production run.

5mm trocars: assistant ports for visualization, retraction, and clip application. 10mm trocars: main working ports for larger instruments, clip appliers, stapler anvils, and specimen retrieval bags. 12mm trocars: linear stapler insertion, specimen retrieval, and robotic arm ports. 15mm trocars: large specimen extraction, large stapler heads, and hand-assist port in hand-assisted laparoscopy.

Looking for a quote or samples? We reply within a few hours.